7000 Defibrillator Monitor (AED and Manual)

Product Detail

Technical specifications

Display

Display Type: 8 inches High-resolution LCD display.

Sweep Speed: 25mm/sec.

Information: Heart Rate, Lead/Pads, Alarm On/Off, Sp02, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

Defibrillator

Waveform: Biphasic

Charge Time: Less than 7 seconds with a new fully charged battery.

Energy Display: Monitor display indicates both selected and delivered energy.

Charge Prompt Type: Voice and visual prompts.

Electrode Impedance Measurement Range: 0-250 ohms.

AED Mode

AED Function: Auto analyzes and charges x3 with programmable auto energy level selection, screen prompts, and voice prompts.

Shockable Rhythms: Ventricular fibrillation with amplitude≥200UV, Ventricular tachycardia with rates≥140bpm, and QRS complex wave duration≥140ms.

Charge Control: Control on device front panel, press key on paddle.

Prompts: Voice and visual prompts.

Manual Mode

Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 Joules.

Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.

ECG Monitoring

Patient Connection: 5-lead ECG cable, or 3-lead ECG cable, paddles.

Lead Selection: Displayed on monitor, paddles, l, II, III, AVR, AVL, AVF, V.

ECG Size: 0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor.

Heart Rate: 20-300BPM.

Heart Rate Alarm: On/Off displayed on monitor, user-selectable.

Smart Alarms: Beeper/Voice prompts indicate shockable rhythm.

SpO2 Module

Measurement Range: 30-100%, +2% between 80%-90%, others + 5%

Alarm Range: User set high limit and low limit

Alarm Accuracy: +10% within setting values

Alarm Time Accuracy: Less than 12 sec

Recorder

Paper: 50mm thermal.

Speed: 12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay.

Printing Method: High-resolution, thermal array print head.

Print-out Modes: Manual or automatic, user-configurable.

On/Off Control: Front panel and paddle.

Automatic Function: 9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge.

Battery

Type: Rechargeable, Ni-MH battery, 12V.

Operating Time: For a new, fully charged battery: 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring.

Additional parameters will affect operating time with different functions.

Option 1

Specification

Pacer (Optional)

Type

VVI

Pulse Type

Rectangular, constant current

Pulse Amplitude

0 to 180 mA±10% or 5 mA (whichever is greater)

Pacing Rate

Variable from 30ppm to 180ppm±1.5% (increments or decrements by a value of 2ppm)

Multi-Function Electrode (MFE) Pads

Multipurpose defibrillator/pacing electrodes

Pause

Pacing pulse frequency reduced by a factor of 4 when activated

Refractory Period

NC (VVI demand do not have this specification)

Pulse Width

(20+1.5ms)

Output Protection

Fully defibrillator protected and isolated

Option 2

Specification

EtCO2 (Optional)

Type of sensor

By-pass

Technical principle

Non-dispersive infrared gas analysis NDIR

Storage condition

-40℃ to 70℃, <90℃ RH, non-condensing

Operating conditions

5℃ to 50℃, 10 to 90℃ RH, non-condensing

Ambient pressure

55-115kPa

Power supply

5V±5% (max ripple 200mVp-p)

TDP

Typical value 120mA Excursion calibration typical value 280mA

Range

0-19.7% (0-150mmHg, or 0-20Kpa)

Resolution

0.1mmHg

Accuracy

0-40mmHg±2mmHg

41-70mmHg±5% of reading

71-100mmHg±8% of reading

101-150mmHg±10% of reading

Respiratory rate

2-150BPM

Respiratory rate measurement accuracy

1%±1BPM

Option 3

Specification

NIBP (Optional)

Measurement unit

mmHg/kPa

Measurement Range

Adult: 10~200mmHg/kPa

Pediatric: 10~200mmHg/kPa

Neonatal: 10~135mmHg/kPa

Resolution

1mmHg

Accuracy

Maximum mean error: 5mmHg

Maximum standard deviation: 8mmHg

Type of sensor

By-pass

Technical principle

Non-dispersive infrared gas analysis NDIR

Storage condition

-40℃ to 70℃, <90% RH, non-condensing

Operating conditions

5℃ to 50℃, 10 to 90% RH, non-condensing

Ambient pressure

55-115kPa

Power supply

5V±5% (max ripple 200mVp-p)

TDP

Typical value 120mA Excursion calibration typical value 280mA

Range

0-19.7% (0-150mmHg, or 0-20kPa)

Resolution

0.1mmHg

Accuracy

0-40mmHg±2mmHg

41-70mmHg±5% of reading 71-100mmHg±8% of reading

101-150mmHg±10% of reading

Respiratory rate

2-150BPM

Respiratory rate measurement accuracy

1%±1BPM


7000 Defibrillator Monitor (AED and Manual)
Long press to look detail
Long by picture save/share
INQUIRY

Inquiry MORE+
  • your name *

  • your email id *

  • your contact phone number

  • your inquiry *

  • Submit

  • Security Code
    Refresh the code
    Cancel
    Confirm

Inquiry Content:


You have no items to require

Add Successfully

Copyright © 2001-2023 Hefei Shendeng Medical Equipment Co., Ltd. All Rights Reserved.

Add WeChat friend to learn more about the product
Use Enterprise WeChat
"Scan" to join the group chat
Copy success!
Add WeChat friend to learn more about the product
I see.